Line 12: Line 12:
|-
|-
| 2-3
| 2-3
| u64, Unknown (always 0)
| u64, Timeout
|}
|}


Line 29: Line 29:


=Description=
=Description=
This terminates the process with the specified process ID. If the unknown u64 value is not 0, the command returns error 0xC8A05801.
This terminates the process with the specified process ID. If the timeout value is not 0 and [[PMApp:PrepareForReboot]] has been called, the command returns error 0xC8A05801.

Latest revision as of 05:03, 20 January 2016

Request

Index Word Description
0 Header code [0x000500C0]
1 Process ID
2-3 u64, Timeout

Response

Index Word Description
0 Header code
1 Result code

Description

This terminates the process with the specified process ID. If the timeout value is not 0 and PMApp:PrepareForReboot has been called, the command returns error 0xC8A05801.