Changes

m
no edit summary
Line 9: Line 9:  
|-
 
|-
 
| 1
 
| 1
| param0
+
| Interrupt
 
|-
 
|-
 
| 2
 
| 2
| param1
+
| Channel
 
|-
 
|-
 
| 3
 
| 3
| 0?
+
| 0x0
 
|-
 
|-
 
| 4
 
| 4
| Event Handle
+
| Event handle (0 = unregister the event that was previous registered)
 
|}
 
|}
 +
 
=Response=
 
=Response=
 
{| class="wikitable" border="1"
 
{| class="wikitable" border="1"
Line 27: Line 28:  
|-
 
|-
 
| 0
 
| 0
| Header code
+
| Header code [0x00150040]
 
|-
 
|-
 
| 1
 
| 1
 
| Result code
 
| Result code
 
|}
 
|}
 +
 +
=Description=
 +
Application should unregister the event by setting handle to zero. If the session was closed before the event was unregistered, it will cause a handle leak in DSP process.
 +
 +
DSP can hold up to 6 concurrent registrations. More than that will cause registration to fail.
 +
 +
Interrupts with interupt=2 are related to [[DSP:WriteProcessPipe|pipes]]. The channel argument is the same as the pipe channel argument. The interrupt is signalled when data is available on the related pipe or when a related event occurs.
50