NWMUDS:PullPacket: Difference between revisions
No edit summary |
|||
(3 intermediate revisions by the same user not shown) | |||
Line 57: | Line 57: | ||
=Description= | =Description= | ||
This | This loads a previously received ''individual'' data frame from state, while connected to the UDS network. This includes all frames received from a node before the node disconnected. The input size must be >= frame_size, otherwise error 0xE10113E9 is returned. | ||
The MaxOutBufSize_wordsize is clamped to 0x172(aka 0x5C8-bytes), but this field isn't really used after that. Instead it just uses MaxOutBufSize, without a size limit. | The MaxOutBufSize_wordsize is clamped to 0x172(aka 0x5C8-bytes), but this field isn't really used after that. Instead it just uses MaxOutBufSize, without a size limit. |